Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Shanghai Journal of Preventive Medicine ; (12): 711-718, 2023.
Article in Chinese | WPRIM | ID: wpr-988909

ABSTRACT

ObjectiveA method was developed for the rapid determination of 18 common disinfection by-products including halogenated oxides and haloacetic acid (HAAs) in drinking water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). MethodThe water sample was filtered by 0.22 μm hydrophilic membrane then the analytes were separated on a PFP (2.1 mm× 100 mm, 2.7 μm) pentafluorophenyl column with 0.1% acetic acid and acetonitrile as mobile phase gradient elution. Ionization in anionic electrospray mode was detected by multi-reaction monitoring (MRM) mode. The external standard method was used for quantitation. ResultsThe correlation coefficients of 18 disinfection by-products were above 0.999 in the corresponding linear range. The average spiked recoveries of 1, 10 and20 times of LOQ of each analyte were 91.6%‒101.8%, and the relative standard deviation (RSD) was 1.2%‒6.4%. The LOD and LOQ were 0.020‒2 μg·L-1 and 0.050‒5 μg·L-1, respectively. ConclusionThis method is simple, sensitive and accurate, and could be used for the routine analysis of 18 common disinfection by-products in drinking water.

2.
Chinese Medical Journal ; (24): 2784-2788, 2014.
Article in English | WPRIM | ID: wpr-318536

ABSTRACT

<p><b>BACKGROUND</b>The bacterial endotoxins test (BET) is a method used to detect or quantify endotoxins (lipo-polysaccharide, LPS) and is widely used in the quality control of parenteral medicines/vaccines and clinical dialysis fluid. It is also used in the diagnosis of endotoxemia and in detection of environment air quality control. Although BET has been adopted by most pharmacopoeias, result judgment algorithms (RJAs) of the test for interfering factors in the BET still differ between certain pharmacopoeias. We have evaluated RJAs of the test for interfering factors for the revision of BET described in the Chinese Pharmacopoeia 2010 (CHP2010).</p><p><b>METHODS</b>Original data from 1 748 samples were judged by RJAs of the Chinese Pharmacopoeia 2010, the Japanese Pharmacopoeia 2011 (JP2011), the European Pharmacopoeia 7.0 (EP7.0), the United States Pharmacopoeia 36 (USP36), and the Indian Pharmacopoeia 2010 (IP2010), respectively. A SAS software package was used in the statistical analysis.</p><p><b>RESULTS</b>The results using CHP2010 and USP36, JP2011, EP7.0, and IP2010 had no significant difference (P = 0.7740). The results using CHP2010 of 1 748 samples showed that 132 samples (7.6%) required an additional step; nevertheless there was no such requirement when using the other pharmacopeias. The kappa value of two RJAs (CHP2010 and EP7.0) was 0.6900 (0.6297-0.7504) indicating that the CHP2010 and other pharmacopoeias have good consistency.</p><p><b>CONCLUSIONS</b>The results using CHP2010 and USP36, JP2011, EP7.0, and IP2010 have different characteristics. CHP2010 method shows a good performance in Specificity, mistake diagnostic rate, agreement rate, predictive value for suspicious rate, and predictive value for passed rate. The CHP2010 method only had disadvantages in sensitivity compared with other pharmacopeias. We suggest that the Chinese pharmacopoeia interference test be revised in accordance with the USP36, JP2011, EP7.0, and IP2010 judgment model.</p>


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Algorithms , Asian People , Diskectomy , Endotoxins , Metabolism , Intervertebral Disc Degeneration , General Surgery , Intervertebral Disc Displacement , General Surgery , Low Back Pain , General Surgery , Retrospective Studies
3.
Chinese Journal of Microbiology and Immunology ; (12): 653-656, 2011.
Article in Chinese | WPRIM | ID: wpr-419530

ABSTRACT

Objective To analyze the laboratory testing data of 2009 pandemic influenza A (H1N1) vaccines during lot release procedure, thus to know the overall quality status of this vaccines.Methods National Institutes for Food and Drug Control(NIFDC) carried out the laboratory test according to the specifications of each manufacture, and the results was analyzed and compared between manufacturer and NIFDC. Results 99.8% of vaccines batches were released by NIFDC, haemagglutinin contents were between 90% to 103 % of labeled values, and testing results slightly differ between manufactures and NIFDC,other items related to safety were all meet specifications. Conclusion The quality of H1N1 vaccines in China were satisfying, the lot release and independent test by NIFDC play important roles to ensure the vaccines' quality.

SELECTION OF CITATIONS
SEARCH DETAIL